How to choose structural timber grades for framing

🪚 Choosing structural timber grades for framing is about matching the correct strength class, treatment level and product type to the load path, exposure conditions and compliance requirements of the build. For Australian trade professionals, the key is understanding where MGP, F-grades

Skill level
Intermediate
Time
1.5–3 hours for assessment, take-off review and supplier confirmation
Trade
Carpentry & Joinery
Updated
1 November 2026

How do you choose structural timber grades for framing in Australia?

🪚 Choosing structural timber grades for framing is about matching the correct strength class, treatment level and product type to the load path, exposure conditions and compliance requirements of the build. For Australian trade professionals, the key is understanding where MGP, F-grades, machine-graded versus visually graded timber, and treated versus untreated framing fit under AS 1684 Residential Timber-Framed Construction and related product standards.

This guide sets out a practical site-and-ordering workflow for selecting framing timber for wall frames, floor systems and roof members, so you can specify the correct 90x45, 140x45, 190x45 or larger section in the right grade, with fewer ordering errors and less risk of non-compliant installation.

What skill level is required for selecting structural timber grades?

Intermediate — Estimated time: 1.5–3 hours for assessment, take-off review and supplier confirmation

What tools are essential for selecting and verifying structural timber grades?

Tape measure 5 m or 8 m for confirming installed and specified member sizes
Framing square / speed square for checking section orientation and member application
Moisture meter suitable for timber framing to verify moisture content where required
Marking pencil and site notebook / digital tablet for take-offs, mark-ups and supplier schedules
AS 1684 span tables in print or digital format for member selection checks
Project plans, engineering details and timber supplier data sheets for grade verification

What common structural timber materials are used for framing in Australia?

🪵 Materials

MGP10 pine framing in common sections such as 90x45 mm, 120x45 mm, 140x45 mm, 190x45 mm
MGP12 pine framing where higher stiffness/strength is required in standard softwood framing sections
F5 / F7 hardwood or softwood framing where visually graded structural timber is nominated
F14 / F17 hardwood members for higher-load applications where specified by engineer or design
H2F treated internal framing timber for termite-protected framing in designated areas
H3 treated timber for external above-ground framing exposure
Untreated kiln-dried framing for internal dry, protected applications where permitted
LVL or engineered timber where spans, point loads or straightness requirements exceed standard sawn framing capability
Supplier grading certificates / treatment certificates for compliance records
Member tags, bundle labels and delivery dockets confirming grade, treatment and species/product line

Safety Requirements

⚠️ Safety

Wear PPE when inspecting, cutting or handling framing timber: safety glasses, hearing protection, P2 dust mask, gloves and steel-cap boots.
Treated timber dust must be controlled with extraction or suitable respiratory protection; follow the manufacturer’s SDS and handling guidance.
Confirm compliance with AS 1684 Residential Timber-Framed Construction, AS 1720 Timber Structures, and relevant product standards such as AS/NZS 1748 for machine stress-graded timber and AS 2858 for visually graded softwood where applicable.
Check state-specific termite management and bushfire requirements before specifying treatment levels, particularly in QLD, NSW, WA, SA and NT termite-prone regions.
For load-bearing framing substitutions, obtain engineer approval where member grade, species or section differs from documented design.
If purchasing new trade tools over $300, review current EOFY instant asset write-off eligibility with your accountant before year-end.

Step-by-Step Guide

Step 1: Identify the framing application and load path

1️⃣ Define the structural role

Start by identifying exactly what the timber is doing: non-load-bearing stud wall, load-bearing external wall, floor joist, bearer, rafter, ceiling joist, lintel support framing or truss-related framing. Grade selection is only correct when tied to the actual structural function.

Review the architectural set, structural plans and engineering notes together. A 90x45 mm stud in an internal partition has a different requirement to a 90x45 mm stud carrying roof and upper-floor loads. Likewise, a 140x45 mm member may be acceptable as a wall plate or nogging but unsuitable as a floor joist at the same grade and span.

💡 Do not select grade by section size alone. The same section can have very different allowable capacities depending on grade, species, moisture condition and restraint.

Step 2: Check the governing standard and design method

2️⃣ Confirm the compliance pathway

For most housing work, use AS 1684 as the primary reference for residential timber-framed construction. The span tables and framing provisions in AS 1684 guide member size and grade selection for standard housing loads and configurations.

Where the project falls outside AS 1684 assumptions—such as unusual point loads, concentrated girder trimmers, large openings, high wind classifications, stacked loads, or non-standard geometry—refer to the structural engineer and AS 1720 Timber Structures. Engineered designs override rule-of-thumb ordering.

If the drawings call up a specific grade such as MGP10, MGP12, F7 or F17, match that exactly unless a formal substitution is approved.

💡 Supplier “equivalent” substitutions are not automatic. A change from one grade system to another still requires verification against the design capacity.

Step 3: Understand the difference between MGP and F-grades

3️⃣ Select the correct grade system

MGP stands for Machine Graded Pine. It is commonly used in Australian residential framing, especially for softwood products like plantation pine. Typical classes are MGP10 and MGP12, with the number indicating stiffness/structural properties used in design.
F-grades are stress grades used across both hardwood and softwood products, commonly seen as F5, F7, F8, F11, F14, F17 and higher. These may be assigned through visual or machine grading, depending on product type and standard.

In practical trade terms:

MGP10 is common for general pine wall framing and standard residential members.
MGP12 is used where extra stiffness or capacity is needed within similar dimensions.
F7 is a common structural grade in visually graded framing and seasoned hardwood applications.
F14 and F17 are more typical for engineered or higher-capacity hardwood structural applications.

When ordering, never assume MGP10 = F7 or similar. They are not interchangeable by label alone. Use the span tables, engineering schedule or supplier structural data.

💡 For pine framing in project homes, MGP10 90x45 mm is common, but floor and roof applications often step up in either depth, spacing control or grade depending on the span table outcome.

Step 4: Determine whether the timber is machine graded or visually graded

4️⃣ Verify how the product has been graded

Machine grading and visual grading are different quality systems. Machine-graded pine typically carries a marked MGP classification and supplier branding. Visually graded timber carries an F-grade and is assessed by allowable natural characteristics and manufacturing quality.

On delivery and during take-off review, check:

grade stamp or bundle tag
treatment code
manufacturer or mill identification
moisture condition if noted
conformance to nominated product standard

Do not accept unmarked structural framing as compliant structural stock unless the supplier provides clear certification and traceability. For inspections and QA, bundle tags and delivery dockets matter just as much as the timber itself.

💡 If the grade stamp is unclear after cutting, retain offcuts with visible branding until inspection sign-off is complete.

Step 5: Match member size and grade to span, spacing and loads

5️⃣ Use span tables properly

Once the application and grade system are clear, check the member depth, thickness, spacing and span against AS 1684 or engineering documentation. A timber grade is only part of the selection; 90x45 mm MGP10 and 90x45 mm MGP12 may both be structural, but allowable spans differ.

Confirm:

member section, e.g. 90x45 mm, 140x45 mm, 190x45 mm, 240x45 mm
member centres, e.g. 450 mm or 600 mm
support conditions
roof, floor or wall loads
wind classification where relevant
whether the member is single, continuous or part of a built-up assembly

For example, a wall stud may satisfy compression requirements at 90x45 mm MGP10, but a floor joist over the same length may require 190x45 mm MGP12 or an engineered alternative.

💡 Trades regularly undercall timber by checking only span and ignoring spacing. The difference between 450 mm and 600 mm centres can change the required section or grade.

Step 6: Decide between treated and untreated framing timber

6️⃣ Specify treatment to suit exposure and termite risk

Treatment selection is based on hazard class, exposure location and local compliance requirements.

General framing rules:

Untreated kiln-dried timber: suitable for internal, dry, protected framing where permitted
H2F treated framing: common for internal framing where termite protection is required
H3 treated timber: for external above-ground exposure such as pergola framing or exposed wall framing prior to enclosure, where specified
Higher hazard classes apply for more severe exposure and are not general internal framing stock

In many Australian regions, internal framing still requires termite risk consideration even where the member is not weather-exposed. Treatment is not about strength grade; it is a separate requirement from structural capacity.

Do not confuse treated with structural. A member must satisfy both:

the required structural grade
the required hazard class / treatment level

💡 A common compliant order description is: 90x45 mm MGP10 H2F pine framing, which identifies size, strength class and treatment in one line.

Step 7: Check seasoned, unseasoned and moisture requirements

7️⃣ Confirm timber condition and stability

Most modern framing supply is seasoned or kiln dried for dimensional stability. This matters for shrinkage, straightness, lining performance and frame movement. For internal wall framing, seasoned material is generally preferred and often expected.

Verify whether the project or supplier is providing:

seasoned softwood framing
unseasoned hardwood framing
engineered timber alternatives for straighter long members

Moisture condition can affect serviceability outcomes, especially for cabinetry interfaces, plasterboard cracking risk and frame movement around openings.

💡 For straight wall framing and reduced callbacks, confirm moisture content and reject badly bowed or twisted members before installation, even if they carry the correct grade.

Step 8: Confirm species, durability and project-specific constraints

8️⃣ Select the right timber product for the environment

Not all framing is plantation pine. Some work still uses seasoned or unseasoned hardwoods, particularly in repair work, tie-ins to older structures, or where specified by engineer or architect. Species selection can affect:

durability
straightness
fastening performance
shrinkage behaviour
cost and availability

For residential framing, plantation pine in MGP10 or MGP12 is the standard supply line in many markets. Hardwood F-grades are typically used where higher strength, matching existing construction, or specific engineering requirements apply.

Where durability and exposure are major factors, consider whether a standard framing product remains appropriate or whether LVL, preservative-treated hardwood or another structural product is a better solution.

💡 In remedial work, matching existing hardwood framing with lightweight pine without engineering review can create differential movement and fixing issues.

Step 9: Review substitutions, engineered products and supplier equivalents

9️⃣ Manage changes properly

If standard sawn framing is unavailable, the next step is not guesswork. Check whether the engineer permits substitution to:

a higher grade in the same section
a deeper member in the same product line
LVL or other engineered timber
an alternative species with equivalent certified structural capacity

Document every approved change. Keep the supplier’s structural literature and confirmation emails on file. On commercial or certifier-sensitive residential work, that record can save substantial rework.

Do not allow site substitutions based solely on “it looks stronger” or “that is what was available in the yard.”

💡 Higher grade does not automatically solve every issue. Serviceability, connection detailing, thickness compatibility and fastening schedules still need checking.

Step 10: Order timber with a full structural description

🔟 Write the order correctly

A professional timber order should clearly identify:

section size
grade
treatment
length
quantity
product type or species if required

Examples:

90x45 mm MGP10 H2F pine studs
140x45 mm MGP12 untreated kiln-dried pine plates
190x45 mm F7 hardwood floor joists
300x45 mm LVL beams to engineer’s schedule

This reduces supplier interpretation errors and ensures the delivered stock matches design intent. Include project area references if practical, such as “Level 1 external walls” or “Garage roof framing”.

💡 If the order value includes specialist saws, lasers or moisture meters above $300, check whether current EOFY instant asset write-off rules may assist the business at tax time.

Step 11: Inspect delivered timber before installation

1️⃣1️⃣ Carry out receiving QA

When the delivery arrives, inspect bundles before dispersing them around the site. Confirm:

size matches order
grade stamp or bundle tag is present
treatment marking matches specification
members are not excessively split, twisted or damaged
engineered products match length and orientation requirements
delivery docket aligns with purchase order

Segregate non-conforming stock immediately and photograph tags and defects. It is far easier to reject a bundle before cutting than to argue compliance once installed.

💡 Keep one photographed tag from every timber pack as part of the job QA file.

Step 12: Record compliance for certifier and handover

1️⃣2️⃣ Maintain documentation

Retain:

supplier invoices
delivery dockets
grading/treatment certificates
engineer approvals for substitutions
photos of tags and installed framing where needed

This is particularly important for structural inspections, termite-related compliance, warranty matters and future rectification works. Good recordkeeping is part of professional framing practice, not administration overhead.

Common Mistakes to Avoid

1.Ordering size only without specifying grade and treatment, for example ordering “90x45 pine” instead of 90x45 mm MGP10 H2F.
2.Assuming MGP and F-grade products are directly interchangeable without checking span tables or engineering documentation.
3.Using untreated internal framing in termite-risk areas where H2F or other management measures are required.
4.Ignoring member spacing, wind classification or load concentration, and selecting timber based only on a rough span estimate.
5.Accepting unmarked or poorly documented structural timber without supplier certification and traceable grading information.

Pro Tips

💡 Build your material schedules with four descriptors every time: size + grade + treatment + length.
💡 Keep current digital copies of AS 1684 span tables on-site; it saves repeated supplier calls and prevents under-specification.
💡 For straight, stable framing around kitchens, joinery walls and tiled wet areas, be selective with crown, bow and moisture condition even when the stock is structurally compliant.
💡 In renovation work, check whether existing framing is hardwood F-grade before ordering replacement pine members.
💡 For long spans, heavily loaded lintel zones or repetitive framing packages, price LVL early; it can reduce call-backs from shrinkage and straightness issues.

Recommended Tools

Protimeter Mini Moisture Meter — reliable for checking timber moisture condition before framing and lining
Stabila 300 mm and 600 mm Spirit Levels — useful for checking bow, crown and installed frame accuracy
Stanley FatMax 8 m Tape Measure — durable for framing set-out and confirming delivered section lengths
Swanson Speed Square — fast reference for member orientation, marking and framing checks
DeWalt or Milwaukee laser distance measurer — efficient for take-offs and material scheduling across larger jobs

Frequently asked questions

What is involved in choose structural timber grades for framing?
🪚 Choosing structural timber grades for framing is about matching the correct strength class, treatment level and product type to the load path, exposure conditions and compliance requirements of the build. For Australian trade professionals, the key is understanding where MGP, F-grades
What skill level do I need for choose structural timber grades for framing?
Intermediate — Estimated time: 1.5–3 hours for assessment, take-off review and supplier confirmation
What are common mistakes when choose structural timber grades for framing?
1. Ordering size only without specifying grade and treatment, for example ordering “90x45 pine” instead of 90x45 mm MGP10 H2F. 2. Assuming MGP and F-grade products are directly interchangeable without checking span tables or engineering documentation. 3. Using untreated internal framing in termite-risk areas where H2F or other management measures are required. 4. Ig
What tools do I need for choose structural timber grades for framing?
This guide includes a comprehensive tools list. Key carpentry & joinery tools are detailed in the Tools Required section.
What is the Australian standard for residential timber framing?
The primary Australian standard for residential timber framing is AS 1684 Residential Timber-Framed Construction. This standard provides prescriptive requirements for timber sizes, grades, and connections, ensuring structural integrity and compliance across various building classes. It is crucial for all Australian tradies to consult the relevant part of AS 1684 for their specific project.
What is the difference between MGP and F-grade timber?
MGP (Machine Graded Pine) timber is strength-graded using mechanical stress-grading machines, ensuring consistent structural properties. F-grades (e.g., F5, F7, F14) are assigned to visually graded timber or sometimes machine-graded timber, indicating characteristic bending strength. According to AS/NZS 1720.1, both systems define structural performance, but MGP typically offers more uniform properties for softwood framing.
When is H2F treated timber required for framing?
H2F treated timber is required for internal framing in areas prone to termite attack, as specified by AS 3660.1 Termite Management. This treatment provides protection against subterranean termites and borers. While not required for weather-exposed or ground-contact applications (which need higher H-levels), H2F is a common specification for wall frames and roof trusses in many Australian regions, particularly north of the Tropic of Capricorn.